SCHILLER SPIROVIT SP-2 SPIROMETER

Combines all the functions of a conventional large spiro device in one handy unit! The device is handed over to the patient with a new disposable mouthpiece for each test in place. Data evaluation and test results are delivered immediately, irrespective of where the tests are carried out. Data are stored on a flash-memory. The SP-2 is equipped with a fast and efficient data evaluation software. Test results can be transferred to a printer via an infrared interface. Curves are printed with high resolution to enable a precise diagnosis.

Features and Benefits

  • Combines all the functions of a conventional large spiro device in one handy unit.
  • Extremely easy to use.
  • Top design and top quality.
  • Excellent value for money.
  • Very low running and maintenance costs.
  • For practice use and home visits FVC, SVC MVV option.
  • Pre/post comparisons.
  • Storage capacity: up to 50 patient tests with 6 measurements each.
  • Flash memory for data storage.
  • Lightning speed data transfer via infrared interface to printer.
  • Battery capacity of up to 30 hours.
  • Disposable mouthpieces designed to minimize the danger of cross contamination.
  • High Quality LCD with a scale of four gray shades (unique).

Materials Included


  • 1 noseclip.
  • 1 disposable mouthpiece, P/N 2.100118.
  • 1 operating manual.

Technical Specifications

  • Technical Data SP-2.
  • Dimension: 85 x 190 x 27 mm; 0.275 kg.
  • Liquid Crystal Display (LCD).
  • Liquid crystal display for graphic and alphanumeric representation.
  • Resolution: 160 x 100 pixel.
  • LCD can be backlighted.
  • Control panel and keyboard: User-friendly rubber keys,
  • 7 function keys, 12-key block.
  • Battery capacity: Approx. 300 complete patient tests.
  • 2 built-in AA 1.5 V alkaline primary batteries.
  • Storage: Flash memory for up to 50 tests.
  • Standard interface: IrDA 1.0.
  • Communication language PCL 3.
  • Printer: IrDA compatible or with IrDA adapter.
  • Hardware option: Calibration syringe, P/N 2.100027.
  • Software option: MVV-Test.
  • Safety standards: IEC/EN 60601-1: 1990; CSA 22.2 and UL 2601.
  • Safety class: BF according to IEC 60601-1.
  • Protection class: IIa according to MDD 93/42/EEC.
  • Standards compliance: ATS, ATS94, OSHA, NIOSH.
  • Conformity:  according 93/42/EEC; FDA K 99 28 23.
  • Measuring method: Pneumotachosensor.
  • Measuring accuracy: According ATS 1994.
  • Flow impedance: < 0.2 mbar s/l at 16 l/s.

Source:Schiller