DRE Waveline EZ Portable Patient Monitor with Touch-Screen

Featuring cutting-edge innovations and impeccable craftsmanship, the DRE Waveline EZ patient monitor is the perfect choice for health care professionals who demand precision, performance and affordability. It features an intuitive touchscreen that helps you quickly and accurately evaluate patient conditions, resulting in better patient care. Utilize the Waveline EZ to monitor ECG, respiration, SpO2, NIBP and temperature; it's also available with EtCO2 monitoring and a printer.
  • Weighs only 6 lbs. One of the most mobile multi parameter monitors on the market.
  • Touch-screen provides immediate operation
  • 8 inch high resolution color display.
  • Simultaneous multi-lead ECG monitoring
  • Advanced ST and arrhythmia detection
  • Graphical and tabular trending
  • Displays five waveforms
  • Battery backup
  • Audible and visual alarms
  • Quick BP readings recall
  • New - Bigger time stamp in upper right corner
  • New - Standby button
  • New - Revised SpO2 pitch tone is still audible when SpO2 rate decreases.
  • New - Volume and Sounds are adjustable and now can be turned off completely
  • New - Option to print Numerical Data Only
  • New - Color of the waveforms can be changed

Physical Dimensions:

  • Height: ~8-1/5 inches
  • Width: 9 inches
  • Length: 4-7/10 inches

Technical Specifications

Safety Approval & Quality System
  • Designed to meet IEC60601-1-1988, EN60601-1-1, EN60601-2
  • Class II Equipment, double insulated
  • Type BF applied parts
  • ISO9001 & EN46001 Certified
Power Requirements
  • Power Supply AC 90-264V/47-63Hz
  • Input Power ≤55VA
  • Fuses Two fuse sockets in the rear panel indicated by "FUSE", OI 5X20, 2A/250V
  • Battery 12V/4.0AH sealed lead-acid
  • Charge time ≥4 hours
  • Operating time ≥2 hours (full recharge)
  • Battery Charging Method Automatic
  • charging after monitor is connected to AC power supply (with charge protection function)
  • Discharge Protection When powered by battery, the monitor will be automatically turned off when battery power is almost used up

Performance Specifications

ECG
  • Input -3-lead ECG cable and standard AAMI line for connection
  • Input - (Optional) 5-lead ECG cable and standard AAMI line for connection
  • Patient Safety Standard IEC60601-1-1988
  • CMRR ≥60dB (Common Mode Rejection Ratio)
  • Heart Rate Range 20 ~ 254bpm ± 1bpm
  • Heart Rate Averaging 8 second average
  • ST Segment Range -0.8 ~ + 0.8mV
  • Interface AAMI 6-pin
  • Lead Selection I, II, III (3 lead mode)
  • I, II, III, aVR, aVL, aVF, V (5 lead mode) (ST and Arrhythmia analysis)
  • Lead Fault Alarm Audible, Visual Input 5-lead ECG patient cable
  • QRS Indicator Audible and Visual Alert
  • Waveform Storage 6 minutes
  • Sweep Speed 12.5/25/50 mm/sec
  • Gain Selection 4mV, 2mV, 1mV, 0.5mV, 0.25mV,Auto
  • Trends 2 hours -> 4 hours -> 8 hours -> 24 hours -> 48 hours
  • Patient Isolation Breakdown voltage 4000VAC 50Hz 60 seconds Leakage current <10μA
  • Frequency width Monitoring mode 0.5 ~ 40Hz (+0.4dB,-3.0dB) Surgery mode 0.5 ~ 20Hz (+0.4dB, -3.0dB) not calibration significant
  • Patient Drive Current <10μA
  • Enclosure Leakage Current <0.1mA
  • Maximum T Wave Rejection Capability 1.2mV
  • Heart Rate Alarm Response Time < 7 seconds
  • Aspect Ratio 0.24 ~ 0.6 sec/mV
  • Alarm Frequency Low alarm: 2-2.4kHz High alarm: 3-3.4kHz
  • Defibrillator Protected & ESIS Protected Tested with 5kV
  • Recovery Time Following Defibrillation <5 seconds

source:DRE